| PRODUCTS - CONCRETE PIPE Overview: Geneva
Pipe Company is one of the most respected concrete product producers in the western
United States. With production from four facilities, Geneva Pipe is able produce
a large variety of concrete products. Our strong production flexibility coupled
with quality engineering, allows Geneva Pipe to easily meet the normal everyday
needs and requirements of specifiers. With a full line of standard products, Geneva
Pipe meets not only your routine needs but your specialty applications as well.
We welcome the opportunity to accomplish the unique and the unusual specification.
The Geneva Pipe product is designed and manufactured for strength, durability,
extended service life, and ease of installation. The product line covers from
12 inches to 144 inches in diameter with most of the variations and variety required
by products of this size and scope. Please contact your Geneva Pipe Representative
for any technical assistance. Circular
Reinforced Concrete Pipe with Rubber Gasket:
ASTM C-76, ASTM 655, AASHTO M170, AASHTO M242
Nominal Pipe ID | Bell
OD | Wall Thickness | Joint
Length | Joint Weight | Square
Feet Area | 12 in | 20.00
in | 2.25 in | 8
Ft | 960 Lbs | 0.79
Sq Ft | 15 in | 23.88
in | 2.25 in | 8
Ft | 1080 Lbs | 1.23
Sq Ft | 18 in | 27.63
in | 2.50 in | 8
Ft | 1552 Lbs | 1.77
Sq Ft | 21 in | 31.75
in | 3.00 in | 8
Ft | 1920 Lbs | 2.41
Sq Ft | 24 in | 35.63
in | 3.00 in | 8
Ft | 2336 Lbs | 3.14
Sq Ft | 27 in | 38.00
in | 4.00 in | 8
Ft | 2842 Lbs | 3.98
Sq Ft | 30 in | 41.34
in | 3.90 in | 8
Ft | 4160 Lbs | 4.91
Sq Ft | 36 in | 51.19
in | 4.65 in | 8
Ft | 5040 Lbs | 7.07
Sq Ft | 42 in | 55.12
in | 4.77 in* | 8/12
Ft | 810 Lbs/Lf | 9.62
Sq Ft | 48 in | 63.00
in | 5.33 in* | 8/12
Ft | 989 Lbs/Lf | 12.57
Sq Ft | 54 in | 70.00
in | 5.50 in | 8/12
Ft | 1117 Lbs/Lf | 15.90
Sq Ft | 60 in | 76.55
in | 6.00 in | 8/12
Ft | 1532 Lbs/Lf | 19.64
Sq Ft | 66 in | 84.00
in | 7.25 in | 12
Ft | 21600 Lbs | 23.76
Sq Ft | 72 in | 88.00
in | 7.00 in | 8/12
Ft | 1842 Lbs/Lf | 28.27
Sq Ft | 84 in | 101.50
in | 8.75 in | 8/12
Ft | 2650 Lbs/Lf | 38.49
Sq Ft | 96 in | 115.50
in | 9.75 in | 8/12
Ft | 3375 Lbs/Lf | 50.27
Sq Ft | Note:
Please contact your Geneva Pipe Representative for any pipe diameter not noted
on the above graph. All pipes manufactured by Geneva Pipe will adhere to ASTM
or AASHTO requirements in regards to reinforcement and concrete compressive strengths.
Pipe dimensions are subject to allowable tolerances and parameters of ASTM and
AASHTO Specifications. * Bell and wall dimensions differ on 12' lengths
- See drawings. Standard Specifications for Reinforced
Concrete Pipe: ASTM C76 – (most current) •
“Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe” ASTM
C76M – (most current) • “Reinforced Concrete Culvert, Storm
Drain, and Sewer Pipe” (Metric) ASTM C655 – (most current)
• “Reinforced Concrete D-Load Culvert, Storm Drain and Sewer Pipe” ASTM
C655M – (most current) • “Reinforced Concrete D-load Culvert,
Storm Drain and Sewer Pipe” (Metric) AASHTO M170 (most current)
• “Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe” AASHTO
M170M (most current) • “Reinforced Concrete Culvert, Storm Drain,
and Sewer Pipe (Metric)” AASHTO M242 (most current) • “Reinforced
Concrete D-load Culvert, Storm Drain, and Sewer Pipe” AASHTO M242M
(most current) • “Reinforced Concrete D-Load Culvert, Storm Drain,
and Sewer Pipe (Metric)” 
Applications:
• Storm Drains • Sanitary Sewers • Culverts •
Underground Stormwater Detention Systems • Irrigation Systems •
Treatment plants Design: The
project engineer should determine all concrete pipe strength classifications (Classes
I, II, III, IV, & V) and installation criteria. In an effort to aid the design
engineer in both the direct and indirect design methods see the Education area
available on the home page of the Geneva Pipe website/catalog. For any additional
information contact your Geneva Pipe Representative. Click
here to view additional pipe drawings. Click
here to review Type 3 fill height charts, standard trench/embankment installations
and soil requirements. Click here
to review Pipe Lifting Devices. For any additional information
contact your local Geneva Pipe Representative: Email: info@genevapipe.com
Phone: 888-225-2416 Back to Top
Circular Non-Reinforced Concrete Pipe with Rubber Gaskets
ASTM C-14, AASHTO M86
Nominal Pipe ID | Bell
OD | Wall Thickness | Joint
Length | Joint Weight | Square
Feet Area | 12 in | 20.00
in | 2.25 in | 8
Ft | 960 Lbs | 0.79
Sq Ft | 15 in | 23.88
in | 2.25 in | 8
Ft | 1080 Lbs | 1.23
Sq Ft | 18 in | 27.63
in | 2.50 in | 8
Ft | 1552 Lbs | 1.77
Sq Ft | 21 in | 27.63
in | 3.00 in | 8
Ft | 1920 Lbs | 2.41
Sq Ft | 24 in | 35.61
in | 3.00 in | 8
Ft | 2336 Lbs | 3.14
Sq Ft | 27 in | 38.00
in | 4.00 in | 8
Ft | 2842 Lbs | 3.98
Sq Ft | 30 in | 41.31
in | 4.13 in | 8
Ft | 4160 Lbs | 4.91
Sq Ft | 36 in | 51.19
in | 4.94 in | 8
Ft | 5040 Lbs | 7.07
Sq Ft | Note:
All non-reinforced concrete pipe manufactured by Geneva Pipe will adhere to the
requirements of ASTM and AASHTO specifications. All dimensions are subject to
allowable tolerances and parameters of those specifications. 
Standard
Specifications for Non-Reinforced Concrete Pipe: ASTM C-14
(most current) • “Concrete Culvert, Storm Drain, and Sewer Pipe” ASTM
C-14M (most current) • “Concrete Culvert, Storm Drain, and Sewer
Pipe (Metric)” AASHTO M86 (most current) • “Concrete
Culvert, Storm Drain, and Sewer Pipe” AASHTO M86M (most current)
• “ Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)” Applications: •
Storm Drains • Culverts • Irrigation Systems Design: The
project engineer should determine all concrete pipe strength classifications (Classes
1, 2, & 3) and installation criteria. In an effort to aid the design engineer
in both the direct and indirect design methods see the Software / Education area
available on the home page of the Geneva Pipe website/catalog or contact your
Geneva Pipe Representative. Click here to view
additional pipe drawings. Click
here to review Pipe Lifting Devices. For any additional information
contact your local Geneva Pipe Representative: Email:
info@genevapipe.com Phone: 888-225-2416 Back
to Top Elliptical Concrete Pipe
with Joint Sealant: ASTM C-507, AASHTO
M207
Nominal Pipe Size | Circular
Equivalent | Joint Weight | Wall
Thickness | Joint Length | Square
Feet Area | 14" x 23" | 18
in | 1665 Lbs | 3.00
in | 8.0 Ft | 1.8
Sq Ft | 19" x 30" | 24
in | 2560 Lbs | 3.50
in | 8.0 Ft | 3.3
Sq Ft | 24" x 38" | 30
in | 3670 Lbs | 3.75
in | 8.0 Ft | 5.1
Sq Ft | 29" x 45" | 36
in | 5000 Lbs | 4.50
in | 7.5 Ft | 7.4
Sq Ft | 34" x 53" | 42
in | 6520 Lbs | 5.00
in | 7.5 Ft | 10.
2 Sq Ft | 38" x 60" | 48
in | 8335 Lbs | 5.
75 in | 8.00 Ft | 12.9
Sq Ft | Note:
For elliptical pipe sizes larger than noted on graph please contact your Geneva
Pipe Representative. Area of reinforcement, number of cages, and concrete compressive
strengths shall be in conformance with appropriate ASTM / AASHTO specifications
for Class HE-A, HE-I, HE-II, HE-III, or HE-IV as required. All dimensions are
subject to allowable tolerances and parameters of those specifications. 
Standard
Specifications for Elliptical Concrete Pipe: ASTM C-507
(most current) • “Reinforced Concrete Elliptical Culvert, Storm
Drain, and Sewer Pipe” ASTM C-507M (most current) • “Reinforced
Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)” AASHTO
M207 (most current) • “Reinforced Concrete Elliptical Culvert,
Storm Drain, and Sewer Pipe” AASHTO M207M (most current) •
“Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)” Applications: •
Storm Drains • Underground Detention Systems • Culverts
• Sanitary Sewers Design: The
project engineer should determine all concrete pipe strength classifications (Classes
HE-I, HE-II, HE-III, & HE-IV) and installation criteria. In an effort to aid
the design engineer in both the direct and indirect design methods see the Software
/ Education area available on the home page of the Geneva Pipe website/catalog.
For any additional information contact your Geneva Pipe Representative. Click
here to view additional pipe drawings. Click
here to review Pipe Lifting Devices. Jacking
/ Microtunneling Pipe 
Uses: •
Storm Drains • Sanitary Sewers • Culverts Specifications: All
specifications are project specific. Please contact Geneva Pipe to assure that
all pipes are manufactured to meet the appropriate project specifications. This
pipe can be designed for both sanitary and storm applications. Please review specific
diameters and the Geneva Pipe Jacking Guidelines located on our Pipe Drawing Page.
For any specific diameter not shown on the Pipe Drawing Page, please call your
Geneva Pipe Representative.
Click here to view Jacked Pipe drawings and guidelines.
Click here to review Pipe Lifting Devices.
For any additional information contact your local Geneva Pipe Representative:
Email: info@genevapipe.com Phone: